logo
Found 90 products for "

medical device repair training

"
Kualitas Pelatihan Perbaikan Peralatan Medis Endoskop Fleksibel Pelatihan Teknisi Perbaikan Peralatan pabrik

Pelatihan Perbaikan Peralatan Medis Endoskop Fleksibel Pelatihan Teknisi Perbaikan Peralatan

Detail Repair Training For Flexible Endoscope Training Detail 1. Introduction of the basic principles and categories of flexiblescope 2. Introduction of flexiblescope system named 3. The name and structure of each part of flexiblescope 4. The introduction of Olympus EVIS LUCERA SPECTRUM system 5.Common fault alanysis of flexible 6. The concept of grade repair and non-grade repair of flexiblescope 7. The correct usage ways of flexiblescope 8. The Maintenance of Flexiblescope 9

Kualitas Perbaikan Peralatan Medis Kasus GE RIC5-9-D PROBE ULTRA-SUON untuk perbaikan pabrik

Perbaikan Peralatan Medis Kasus GE RIC5-9-D PROBE ULTRA-SUON untuk perbaikan

GE RIC5-9-D Probe Fault: Dome loose, straight relief tiny broken, with error on machine. Solution: Replace dome and oiling. Repair cost : $***. Common Issues with the GE RIC5-9-D Ultrasound Probe: Image Artifacts/Dropouts: These can manifest as lines, shadowing, or a complete loss of image in certain areas. Common causes include: Crystal Damage: Piezoelectric crystals within the transducer array can become damaged due to physical impact, overheating, or degradation over time.

Kualitas Perbaikan Peralatan Medis Kasus Stryker 30o 0502-503-030 laproscope untuk perbaikan pabrik

Perbaikan Peralatan Medis Kasus Stryker 30o 0502-503-030 laproscope untuk perbaikan

Stryker 30º 0502-503-030 laproscope, SN:103**** Fault: Image blur, objective lens loose without glue, inner optical parts broken. Solution: Add glue for objective lens, replace inner optical parts, clean and adjust optical system, seal with eyepiece. Repair cost: $*** Common Issues with the Stryker 0502-503-030 Laparoscope: 1.Fogging/Obscured Vision: This is a frequent issue during laparoscopic procedures. It can be caused by temperature differences between the endoscope and

Kualitas OLYMPUS CF-HQ190L Peralatan Kesehatan Cases Repair Tool Case pabrik

OLYMPUS CF-HQ190L Peralatan Kesehatan Cases Repair Tool Case

OLYMPUS CF-HQ190L Repair Problem: 1, Image display;2, Light bundle broken about 10%;3, Insertion tube is ok;4, Biospy channel worn and leaking;5, The upper angle broken, helix tube and bending section were worn;6, Light guide tube indented and the back cover is leaking;7, The EL-connector is not good sealed and leaking. Solution: Replace biopsy channel, bending section, wire, helix tube, light guide tube, rubber Company Profile Guangzhou Careutech Co., Ltd. supplies medical

Kualitas Kasus Perbaikan Peralatan Medis LINVATEC HD 4300 Artroskop untuk perbaikan pabrik

Kasus Perbaikan Peralatan Medis LINVATEC HD 4300 Artroskop untuk perbaikan

LINVATEC HD 4300 Arthroscope for repair, SN: 62**** Fault: Image with black shadow; eyepiece with scratches, inner optical parts broken. Replace objective lens, inner optical parts, clean and adjust optical system, seal with eyepiece. Image Quality Related Issues: 1.Fogging or Blurry Vision: This is a frequent problem in arthroscopy. It can be due to condensation inside the endoscope, debris on the lens, or issues with the camera system. 2.Dark or Dim Image: This could be

Kualitas Peralatan medis perbaikan Kasus Olympus CF-H190L Kolonoskop untuk perbaikan pabrik

Peralatan medis perbaikan Kasus Olympus CF-H190L Kolonoskop untuk perbaikan

Olympus CF-H190L Colonoscope for repair,SN:261****. Fault:Light bundle broken,biopsy tube worn,water air tube leakage,bending section deformation,wire helix tube worn. Solution:Replace the bending section,wire,helix tube,air tube and rubber.PS:Warranty for replace parts only. Repair time:7 working days. Repair price:$****. Warranty:90 days. Guangzhou Care techonoly Co., Ltd. is a company dedicated to the supply of medical equipment maintenance tools, maintenance accessories,

Kualitas Olympus A4674A Autoclavable Hysteroscope untuk perbaikan pabrik

Olympus A4674A Autoclavable Hysteroscope untuk perbaikan

Olympus A4674A Autoclavable Hysteroscope for repair ► Brief Description Fault: 1. Image blur and black shadow. 2. Rod lens broken. 3. Outer tube bending and transformation. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model A4674A Fault 1. Image blur

Kualitas C5-2 Probe Konveksi Untuk Perbaikan Bagian Perangkat Medis pabrik

C5-2 Probe Konveksi Untuk Perbaikan Bagian Perangkat Medis

C5-2 Convex Probe For Repair ► Brief Description Fault: Strain relief damage, cable broken. Solution: Replace strain relief, repair cable. ►Problem & Solutoin Model C5-2 Convex Fault Strain relief damage, cable broken Solution Replace strain relief, repair cable ► Common Issues with C5-2 Probes Dead or flickering elements (image dropouts, black lines) Cable damage (broken wires near the connector or handle) Lens damage (cracks, delamination, or wear) Acoustic array failure

Kualitas Sonde perut GE 4C-RS untuk perbaikan pabrik

Sonde perut GE 4C-RS untuk perbaikan

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS Probe Image dropouts / Black lines Acoustic lens damage Cable damage Connector damage Oil leakage If your instrument has any of the above problems or others, please feel free to

Previous Next
Previous
Page 1 dari 10
Next