Kualitas 1898200T M4 Straighthot Microdebrider dan Handpiece untuk perbaikan pabrik

1898200T M4 Straighthot Microdebrider dan Handpiece untuk perbaikan

1898200T M4 Straightshot Microdebrider and Handpiece for repair ► Brief Description Fault: 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside is full of disinfection residue, motor corrosion. 3) The rotation direction of the knife head is stuck. 4) Handle paint off, internal ...

Kualitas GE RIC6-12-D probe endocavity untuk perbaikan pabrik

GE RIC6-12-D probe endocavity untuk perbaikan

GE RIC6-12-D endocavity probe for repair ► Brief Description Fault: Lens problem. Solution: Replace lens,Clean cable. ►Problem & Solutoin BrandGEModelRIC6-12-DFaultLens problemSolutionReplace lens,Clean cable ► Common issues with RIC6-12-D Probe Dome Damage and Fluid LeaksImage Dropouts (Dead ...

Kualitas Karl Storz 27005BA endoskop untuk perbaikan pabrik

Karl Storz 27005BA endoskop untuk perbaikan

Karl Storz 27005BA endoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens ...

Kualitas OLYMPUS TJF-Q180V DUODENOSCOPE untuk perbaikan pabrik

OLYMPUS TJF-Q180V DUODENOSCOPE untuk perbaikan

OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR ► Brief Description Fault: 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leakage. Solution: Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and ...

Kualitas L15-7io Sonde linier untuk perbaikan pabrik

L15-7io Sonde linier untuk perbaikan

L15-7io Linear probe for repair ► Brief Description Fault: Lens problem. Solution: Replace probe lens. ►Problem & Solutoin Model L15-7io Fault Lens problem Solution Replace probe lens ► Common issues with L15-7io probe Cable and Connector Issues Acoustic Lens Damage Crystal/Element Failure Housing...

Kualitas Olympus ENF-GP fiber nasofaringoskop laryngoskop untuk perbaikan pabrik

Olympus ENF-GP fiber nasofaringoskop laryngoskop untuk perbaikan

Olympus ENF-GP fiber nasopharyngeal laryngoscope for repair ► Brief Description Fault: 1. Image with black point and image bundle broken 2. Light bundle aged 3. Insert tube aging and wrinkle 4. Bending section deformation 5. Angle with not enough 6. Rubber abrasion Solution: Replace image bundle; ...

Kualitas OLYMPUS TJF-Q180V Duodenoskop Elektronik Untuk Diperbaiki pabrik

OLYMPUS TJF-Q180V Duodenoskop Elektronik Untuk Diperbaiki

OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair ► Brief Description Inspection Results: 1. Image display is available; 2. The light bundle brightness is acceptable; 3. The insertion tube is worn; 4. The light guide tube is worn; 5. The angle is insufficient, the snake bone, steel wire and helix ...

Kualitas Probe Array Bertahap Toshiba PST-25BT Untuk Perbaikan pabrik

Probe Array Bertahap Toshiba PST-25BT Untuk Perbaikan

Toshiba PST-25BT Phased Array Probe For Repair ► Brief Description Fault: Housing break, image weak, crystal aging. Solution: Replace crystal and housing. ►Problem & Solutoin Brand Toshiba Model PST-25BT Fault Housing break, image weak, crystal aging Solution Replace crystal and housing ► Common ...

Kualitas T-D0022 Alat Perbaikan Drill Medis Untuk SYNTHES 530.610 Baterai Dioperasikan Reciprocator Drill pabrik

T-D0022 Alat Perbaikan Drill Medis Untuk SYNTHES 530.610 Baterai Dioperasikan Reciprocator Drill

Product Description 1. Introduction T-D0022 Repair tool for SYNTHES 530.610 Battery Operated Reciprocator Drill Brand-new Perfectly repair drill without scratch 2. Characteristics and Advantages Number:T-D0022 Features: Durable, Portable, Multi-functional Advantages: High Quality Materials, Precise ...