medical device repair training
"
T-R0039 Alat perbaikan endoskop untuk lampu pemanas endoskop kaku
Product Description 1. Introduction T-R0039 Repair tool for Storz Wolf Olympus Stryker Rigid Endoscope Heating Lamp Brand-new Perfectly repair rigid endoscope without scratch 2. Characteristics and Advantages Number:T-R0039 Features: Durable, Portable, Multi-functional Advantages: High Quality ...
GE 4D3C-L 4D Transducer Konveksi Untuk Perbaikan
GE 4D3C-L 4D Convex Transducer For Repair ► Brief Description Fault: 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. Solution:Replace the dome, dome tube; repair electric motor. ►Problem & Solutoin BrandGEModel4D3C-LFault1.Probe dome ...
Olympus LTF-160 thoracoscope untuk perbaikan
Olympus LTF-160 thoracoscope for repair ► Brief Description Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the ...
Kolonoskop Elektronik OLYMPUS CF-H180AL Untuk Perbaikan
OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and ...
Gastroskopi Elektronik SonoScape EG-500 Untuk Perbaikan
SonoScape EG-500 Electronic Gastroscopy For Repair ► Brief Description Inspection Results: 1. No image display, CMOS water ingress fault; 2. 20% of the light bundle is broken; 3. There are bite marks on the insertion tube in multiple places; 4. The biopsy tube is worn out and not smooth; 5. The ...
Alat Perbaikan Endoskop Tepat Rigid Opposing Tool Kit Untuk Lokakarya Pemeliharaan
Rigid Endoscope Repair Tool Oppening Tool Kit for Maintenance Workshop Disassemble and assemble tool for rigid endoscope repair workshop Guangzhou Careutech Co., Ltd. is a company dedicated to the supply of medical equipment maintenance tools, maintenance accessories, professional maintenance ...
R Wolf 7326071 ureteroskop untuk perbaikan
R Wolf 7326071 ureteroscope for repair ► Brief Description Fault: The image has spots,image bundle aging,light bundle broken;Insert tube aging;Biopsy channel worn and leakage;Bending section,wire and helix tube were worn. Solution: Replace the light bundle,image bundle,rubber,biopsy channel,helix ...
Kepala kamera STRYKER 1188-210-105 untuk diperbaiki
STRYKER 1188-210-105 camera head for repair ► Brief Description Fault: Image with interrupt. Cable aging. Solution: Replace compatible new cable and connector. ►Problem & Solutoin Brand STRYKER Model 1188-210-105 Fault Image with interrupt. Cable aging Solution Replace compatible new cable and ...
Probe ultrasound array linier Aloka UST-5413 untuk diperbaiki
Aloka UST-5413 linear array ultrasound probe for repair ► Brief Description Fault: Lens break. Solution: Replace lens. ►Problem & Solutoin BrandAlokaModelUST-5413FaultLens breakSolutionReplace lens ► Common issues with UST-5413 Probe Image dropouts or black linesAcoustic lens damageCable damageConne...