Kualitas Perbaikan Peralatan Medis Kasus GE RIC5-9-D PROBE ULTRA-SUON untuk perbaikan pabrik

Perbaikan Peralatan Medis Kasus GE RIC5-9-D PROBE ULTRA-SUON untuk perbaikan

GE RIC5-9-D Probe Fault: Dome loose, straight relief tiny broken, with error on machine. Solution: Replace dome and oiling. Repair cost : $***. Common Issues with the GE RIC5-9-D Ultrasound Probe: Image Artifacts/Dropouts: These can manifest as lines, shadowing, or a complete loss of image in ...

Kualitas OLYMPUS CF-HQ190L Peralatan Kesehatan Cases Repair Tool Case pabrik

OLYMPUS CF-HQ190L Peralatan Kesehatan Cases Repair Tool Case

OLYMPUS CF-HQ190L Repair Problem: 1, Image display;2, Light bundle broken about 10%;3, Insertion tube is ok;4, Biospy channel worn and leaking;5, The upper angle broken, helix tube and bending section were worn;6, Light guide tube indented and the back cover is leaking;7, The EL-connector is not ...

Kualitas GE 4D3C-L 4D Transducer Konveksi Untuk Perbaikan pabrik

GE 4D3C-L 4D Transducer Konveksi Untuk Perbaikan

GE 4D3C-L 4D Convex Transducer For Repair ► Brief Description Fault: 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. Solution:Replace the dome, dome tube; repair electric motor. ►Problem & Solutoin BrandGEModel4D3C-LFault1.Probe dome ...

Kualitas Sonde perut GE 4C-RS untuk perbaikan pabrik

Sonde perut GE 4C-RS untuk perbaikan

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS ...

Kualitas S5-2 Probe jantung untuk diperbaiki pabrik

S5-2 Probe jantung untuk diperbaiki

S5-2 Cardiac probe for repair Fault: Lens problem, cable broken, without strain relief. Solution: Replace probe lens, repair cable, replace strain relief. ►Problem & Solutoin Model S5-2 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, repair cable, replace strain ...

Kualitas Olympus LTF-160 thoracoscope untuk perbaikan pabrik

Olympus LTF-160 thoracoscope untuk perbaikan

Olympus LTF-160 thoracoscope for repair ► Brief Description Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the ...

Kualitas Kolonoskop Elektronik OLYMPUS CF-H180AL Untuk Perbaikan pabrik

Kolonoskop Elektronik OLYMPUS CF-H180AL Untuk Perbaikan

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and ...

Kualitas Gastroskopi Elektronik SonoScape EG-500 Untuk Perbaikan pabrik

Gastroskopi Elektronik SonoScape EG-500 Untuk Perbaikan

SonoScape EG-500 Electronic Gastroscopy For Repair ► Brief Description Inspection Results: 1. No image display, CMOS water ingress fault; 2. 20% of the light bundle is broken; 3. There are bite marks on the insertion tube in multiple places; 4. The biopsy tube is worn out and not smooth; 5. The ...

Kualitas Olympus Flexible Endoscope Air & Water Tube A/W Transparent Tube pabrik

Olympus Flexible Endoscope Air & Water Tube A/W Transparent Tube

Olympus/ Pentax/ Fuji A/W Tube ► Brief Description The "air/water channel" is a critical part of a flexible endoscope's function. The tube you are referring to is most commonly known as the Air/Water Valve Tube or A/W Tube . It's a small, transparent, and highly flexible tube that connects the air ...